Vernier Software and Technology - Celebrating 35 years
Vernier Software & Technology
Figure for LabQuest® 2 HardwareFigure for LabQuest® 2 Hardware
Figure for LabQuest® 2 HardwareFigure for LabQuest® 2 Hardware
Figure for LabQuest® 2 HardwareFigure for LabQuest® 2 Hardware
Product image for LabQuest® 2 HardwareProduct image for LabQuest® 2 Hardware
Product image for LabQuest® 2 HardwareProduct image for LabQuest® 2 Hardware
Product image for LabQuest® 2 HardwareProduct image for LabQuest® 2 Hardware
Product image for LabQuest® 2 HardwareProduct image for LabQuest® 2 Hardware
Product image for LabQuest® 2 HardwareProduct image for LabQuest® 2 Hardware
Product image for LabQuest® 2 HardwareProduct image for LabQuest® 2 Hardware

Technical Specifications

Display

  • 11.2 cm x 6.7 cm (13.1 cm diagonal) screen
  • 800 x 480 pixel color display at 188 dpi
  • LED backlight
  • Portrait or landscape screen orientation
  • High-contrast mode for outdoor visibility

Processor

  • 800 MHz Application Processor

Connectivity

  • Wi-Fi 802.11 b/g/n
  • Bluetooth Smart for WDSS and Go Wireless Sensors

User Interface

  • Resistive touch screen
  • Touch and stylus navigation for efficiency and precision

Data Acquisition

  • 100,000 samples per second
  • 12-bit resolution
  • Built-in GPS, 3-axis accelerometer, ambient temperature, light, and microphone

Environmental Durability

  • Operating Temperature: 0 – 45°C
  • Storage Temperature: -30 – 60°C
  • Splash resistant
  • Rugged enclosure designed to withstand a fall from lab bench

Size and Weight

  • Size: 8.8 cm x 15.4 cm x 2.5 cm
  • Weight: 350 g

Ports

  • 5 sensor channels
  • USB port for sensors, flash drives, and peripherals
  • USB mini port
  • DC power jack
  • MicroSD/MMC slot
  • Audio in and out

Storage

  • 200 MB
  • Expandable with MicroSD and USB flash drive

Power

  • Rechargeable, high-capacity battery
  • DC charging/powering through external adapter (included)

Compatible Sensors

LabQuest 2 is compatible with over 70 Vernier sensors to support multi-variable experiments and data-logging activities.

LabQuest 2LabQuest 2 and LabQuest App96 sensors

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a Motion Detector USB Cable or an Easy to Go! Adapter to connect to a standard USB port
  3. Requires a BNC electrode
  4. Connect this sensor via Bluetooth® for best results.
  5. Requires an Easy to Go! adapter
  6. Connect this sensor via USB. Wireless data collection is not supported.
  7. Requires a Go Wireless USB Radio when used with some LabQuest 2 models
  8. Sensor does not auto-ID; manual setup is required.
  9. Requires a Gas Pressure Sensor
  10. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.

Sensors Supported in the Future

ComputersComputers and Graphical Analysis for Computers96 sensors

Supported Sensors

Compatibility Notes

  1. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. Future software updates will support the use of this sensor with LabQuest connected via USB to computers or Chromebooks.
  2. Requires a Motion Detector Cable to connect to a DIG port on the interface
  3. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. This sensor is not supported when connected to a computer or Chromebook via USB.
  4. Requires a BNC electrode
  5. Data can be collected using the sensor’s default calibration. Future software updates will support calibration modifications.
  6. This software cannot apply digital filters to EKG data.
  7. Requires an Easy to Go! adapter
  8. Connect the sensor to a Chromebook via USB for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 when LabQuest 2 is connected to a Chromebook via Wireless Data Sharing.
  9. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. This sensor is not supported when connected to a computer or Chromebook via USB or Bluetooth.
  10. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. This sensor is not supported when connected to a computer or Chromebook via Bluetooth.
  11. Software does not support the Data Tagging feature that is typically used with this sensor.
  12. Requires an additional signal source, such as LabQuest 2 running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  13. Sensor does not auto-ID; manual setup is required.
  14. Requires a Gas Pressure Sensor
  15. Software does not support baseline adjustment, which is necessary for lung capacity measurements.
  16. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  17. Software cannot calculate resistance or power data.
  18. This interface/software combination can only collect force data; displacement measurements are not supported.

Sensors Supported in the Future

ComputersComputers and Logger Pro84 sensors

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Requires a Heart Rate Receiver to connect to an interface
  4. Requires an additional signal source, such as LabQuest 2 running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  5. Sensor does not auto-ID; manual setup is required.
  6. Requires a Gas Pressure Sensor
  7. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.

ComputersComputers and Logger Lite72 sensors

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector Cable to connect to a DIG port on the interface
  2. Requires a BNC electrode
  3. Requires a Heart Rate Receiver to connect to an interface
  4. Requires an additional signal source, such as LabQuest 2 running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  5. Requires a Gas Pressure Sensor
  6. Software does not support baseline adjustment, which is necessary for lung capacity measurements.
  7. This interface/software combination auto IDs the VSMT Force sensor; displacement measurements require a Logger Lite file found at www.vernier.com/til/3621/

ChromebookChromebook and Graphical Analysis for Chrome96 sensors

Supported Sensors

Compatibility Notes

  1. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. Future software updates will support the use of this sensor with LabQuest connected via USB to computers or Chromebooks.
  2. Requires a Motion Detector Cable to connect to a DIG port on the interface
  3. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. This sensor is not supported when connected to a computer or Chromebook via USB.
  4. Requires a BNC electrode
  5. Data can be collected using the sensor’s default calibration. Future software updates will support calibration modifications.
  6. This software cannot apply digital filters to EKG data.
  7. Requires an Easy to Go! adapter
  8. Connect the sensor to a Chromebook via USB for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 when LabQuest 2 is connected to a Chromebook via Wireless Data Sharing.
  9. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. This sensor is not supported when connected to a computer or Chromebook via USB or Bluetooth.
  10. Full support of this sensor is only available when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing. This sensor is not supported when connected to a computer or Chromebook via Bluetooth.
  11. Software does not support the Data Tagging feature that is typically used with this sensor.
  12. Requires an additional signal source, such as LabQuest 2 running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  13. Sensor does not auto-ID; manual setup is required.
  14. Requires a Gas Pressure Sensor
  15. Software does not support baseline adjustment, which is necessary for lung capacity measurements.
  16. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.
  17. Software cannot calculate resistance or power data.
  18. This interface/software combination can only collect force data; displacement measurements are not supported.

Sensors Supported in the Future

Mobile DevicesMobile Devices and Graphical Analysis for iOS96 sensors

For All Supported Sensors

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector USB Cable or an Easy to Go! Adapter to connect to a standard USB port
  2. Requires a Motion Detector Cable to connect to a DIG port on the interface
  3. Requires a BNC electrode
  4. Connect this sensor via Bluetooth® for best results.
  5. Requires an Easy to Go! adapter
  6. Requires an additional signal source, such as LabQuest 2 running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Sensor does not auto-ID; manual setup is required.
  8. Requires a Gas Pressure Sensor
  9. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.

Sensors Supported in the Future

Mobile DevicesMobile Devices and Graphical Analysis for Android96 sensors

For All Supported Sensors

Supported Sensors

Compatibility Notes

  1. Requires a Motion Detector USB Cable or an Easy to Go! Adapter to connect to a standard USB port
  2. Requires a Motion Detector Cable to connect to a DIG port on the interface
  3. Requires a BNC electrode
  4. Connect this sensor via Bluetooth® for best results.
  5. Requires an Easy to Go! adapter
  6. Requires an additional signal source, such as LabQuest 2 running the Power Amplifier app or a computer running the Power Amplifier Function Generator Software, to control the Power Amplifier output
  7. Sensor does not auto-ID; manual setup is required.
  8. Requires a Gas Pressure Sensor
  9. Use with an electrode such as a pH Sensor, Conductivity Probe, or ORP Sensor.

Sensors Supported in the Future

What’s Included

  • Vernier LabQuest 2 interface
  • 1 stylus
  • Stylus tether
  • Computer connection (USB) cable
  • AC power adapter
  • Quick-start guide

Free Software Updates

Get new features and enhancements with free software updates to LabQuest 2.

Download the latest LabQuest update

Ordering Information

All prices are for U.S. educators.

NameOrder CodePriceQuantity
LabQuest 2LABQ2$329
Optional Accessories
LabQuest 2 Charging StationLQ2-CRG$119
LabQuest 2 Lab ArmorLQ2-ARMOR$15
LabQuest 2 StandLQ2-STN$5
LabQuest Battery Boost 2LQ-BOOST2$119
LabQuest SD CardLQ-SD$12
LabQuest ViewerLQ-VIEW$79
Vernier LanyardLQ-LAN$5

Educational use only: Vernier products are designed for educational use. They are not appropriate for industrial, medical, or commercial applications. Product usage disclaimer »

Go to top