Vernier Structures & Materials Tester (VSMT) Troubleshooting and FAQs

Vernier Structures & Materials Tester, order code VSMT, $999
Specifications and User Guide

TROUBLESHOOTING
- Primary Test: The VSMT Force sensor will auto-ID with supported releases of software.
- Secondary Test: The VSMT Displacement sensor will not auto-ID, but can be selected from the list of digital sensors with supported releases of software.

Three experiment files are released with the supported versions of Logger Pro. The files are:
Structure Prototype - testing a single structure or beam as part of an engineering design process
Structures Comparison - running a class competition where results can be compared side-by-side
Elastic Modulus Moment of Inertia - testing a uniform beam for force and displacement in order to calculate the Modulus of Elasticity or Moment of Inertia

-Minimum software version: LP3 version 3.9, Logger Lite version 1.8, LabQuest 2 version 2.5, or LabQuest version 1.7.3

RELATED ARTICLES
TIL 3346: I can't get my structures and materials tester displacement reading.
TIL 3349: Can I use TI Nspire to collect data from the Vernier Structures and Materials Tester?
TIL 3412: My Vernier Structures & Materials Tester (VSMT) arrived with broken parts.
TIL 3418: Will the VSMT work with SensorDAQ and LabVIEW?
TIL 3451: Why are the force readings on my Structures and Materials Tester (VSMT) noisy?
TIL 3457: Is the tackle kit for Vernier Structures & Materials Tester (VSMT-TK) able to handle 1000 N of force?
TIL 3463: Why is my VSMT force sensor stuck at 1000 N?
TIL 3464: How do I remove the force sensor from the Vernier Structures and Materials Tester (VSMT)?
TIL 3481: Why won't the bar graph show results for my bridge competition?
TIL 3497: How do I tighten the force sensor in my Structures and Materials Tester (VSMT)?
TIL 3595: Trust Tester Accessory for Structures & Materials Tester Troubleshooting and FAQs
TIL 3621: Can I use the Vernier Structures and Materials Tester with Logger Lite?
TIL 3704: Can I use the VSMT to conduct 3-point and 4-point flexural testing?
TIL 4296: Can I use the Structures Tester for the Science Olympiad Boomilever event?

SPECIFICATIONS
See user manual.

CALIBRATION
The VSMT Force sensor should not require calibration. A 2-point calibration is recommended if necessary.

The VSMT Displacement sensor cannot be calibrated.