{"id":14699,"date":"2022-03-22T11:58:41","date_gmt":"2022-03-22T18:58:41","guid":{"rendered":"https:\/\/www.vernier.com\/til\/?p=14699&#038;preview=true&#038;preview_id=14699"},"modified":"2025-05-01T13:42:25","modified_gmt":"2025-05-01T20:42:25","slug":"gotemp-troubleshooting-and-faqs","status":"publish","type":"post","link":"https:\/\/www.vernier.com\/til\/14699","title":{"rendered":"EasyTemp Troubleshooting and FAQs"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h3 class=\"wp-block-heading\"><a href=\"\/product\/easytemp\/\">EasyTemp<\/a> (<nobr>EZ-TMP<\/nobr>)<\/h3>\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.vernier.com\/manuals\/ez-tmp\/\">Specifications and User Manual<\/a><\/li>\n<li><a href=\"\/til\/19544\/\">Which EasyTemp temperature probe do I have?<\/a><\/li>\n<\/ul>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1488-768x1024.jpg\" alt=\"\" class=\"wp-image-19540\" style=\"width:150px;height:auto\" srcset=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1488-768x1024.jpg 768w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1488-450x600.jpg 450w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1488-1152x1536.jpg 1152w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1488-1536x2048.jpg 1536w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1488-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1490-768x1024.jpg\" alt=\"\" class=\"wp-image-19547\" style=\"width:149px;height:auto\" srcset=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1490-768x1024.jpg 768w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1490-450x600.jpg 450w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1490-1152x1536.jpg 1152w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1490-1536x2048.jpg 1536w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/03\/IMG_1490-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<h3 class=\"wp-block-heading\">Supported Calculator Apps<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong><a href=\"https:\/\/www.vernier\/til\/5078\">EasyData<\/a><\/strong>\u2014for TI-84 Plus calculators and TI-SmartView emulator software<\/li>\n<li><strong><a href=\"https:\/\/www.vernier.com\/til\/5061\">DataQuest<\/a><\/strong>\u2014for TI-Nspire handhelds and computer software<\/li>\n<\/ul>\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h3 class=\"wp-block-heading\">Troubleshooting<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>Primary Test: <\/strong>Plug in the sensor and run the data-collection program. Hold the tip of the sensor in your hand and check for the temperature readings to change.<\/li>\n<li><strong>Secondary Test:<\/strong> Verify the LED on EasyTemp is green. If your LED is not green, see:\u00a0<a href=\"\/til\/2113\/\">The LED on my Go! device or LabQuest Mini is not green. What does that mean?<\/a><\/li>\n<\/ul>\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h3 class=\"wp-block-heading\">Additional Troubleshooting<\/h3>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/til\/2562\/\">Texas Instruments (TI) Troubleshooting and FAQs<\/a><\/li>\n<li><a href=\"\/til\/1721\/\">Which Vernier and Texas Instruments products are compatible with TI-Nspire products?<\/a><\/li>\n<li><a href=\"\/til\/2039\/\">Can an EasyTemp or EasyLink be used with LabQuest?<\/a><\/li>\n<li><a href=\"\/til\/3086\/\">TI SmartView Troubleshooting and FAQs<\/a><\/li>\n<li><a href=\"\/til\/1469\/\">Can I use Go! devices with TI-84 Plus or TI-Nspire calculators or Easy devices with computers or Chromebooks?<\/a><\/li>\n<li><a href=\"\/til\/4364\/\">Should I buy EasyTemp, Go!Temp, or Go Direct Temp to work with Texas Instruments calculators, computers, and Chromebooks?<\/a><\/li>\n<li><a href=\"\/til\/2406\/\">Can I connect an EasyTemp, EasyLink or CBR 2 directly to a TI-Nspire Lab Cradle?<\/a><\/li>\n<li><a href=\"\/til\/2405\/\">Can I use Go! and Easy products at the same time as the TI-Nspire Lab Cradle?<\/a><\/li>\n<li><a href=\"\/til\/2407\/\">Can I use two TI-Nspire Lab Cradles or two EasyLinks or Go!Links connected to the same TI-Nspire or computer?<\/a><\/li>\n<li><a href=\"\/til\/1718\/\">What data collection hardware works with TI-Nspire products?<\/a><\/li>\n<li><a href=\"\/til\/1527\/\">EasyData quits in the middle of data collection with my EasyTemp or EasyLink.<\/a><\/li>\n<li><a href=\"\/til\/19536\/\">My EasyTemp is not working with my TI-84 Plus CE Python Edition calculator, what can I do?<\/a><\/li>\n<\/ul>\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h3 class=\"wp-block-heading\">Specifications<\/h3>\n<ul class=\"wp-block-list\">\n<li>Range: \u201320\u00b0C to 115\u00b0C<\/li>\n<li>Maximum temperature that the sensor can tolerate without damage: 150\u00b0C<\/li>\n<li>Resolution: 0.07\u00b0C<\/li>\n<li>Accuracy: \u00b1 0.5\u00b0C<\/li>\n<li>Response time: 4 s (to 90% of full reading in water)<\/li>\n<\/ul>\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h3 class=\"wp-block-heading\">Calibration<\/h3>\n<p>Calibrate? EasyTemp is very nicely calibrated when shipped. Most never need to calibrate. EasyTemp uses a linear calibration equation and can be calibrated if required using a two point calibration. See the data collection app user manual for details on how to calibrate a sensor.<\/p>\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h3 class=\"wp-block-heading\">Related Products<\/h3>\n<ul class=\"wp-block-list\">\n<li><a href=\"\/product\/easy-to-go-adapter\/\">Easy to Go! Adapter<\/a> (<nobr>MINI-USB<\/nobr>), for connecting EasyTemp to computers or Chromebooks<\/li>\n<li><a href=\"\/product\/gotemp\/\">Go!Temp<\/a> (<nobr>GO-TEMP<\/nobr>), for use with calculator emulator software<\/li>\n<li><a href=\"\/product\/easylink\/\">EasyLink<\/a> (<nobr>EZ-LINK<\/nobr>), calculator interface required for temperature sensors listed below<br \/>\u26ac <a href=\"\/product\/stainless-steel-temperature-probe\/\">Stainless Steel Temperature Probe<\/a> (<nobr>TMP-BTA<\/nobr>)<br \/>\u26ac <a href=\"\/product\/extra-long-temperature-probe\/\">Extra-Long Temperature Probe<\/a> (<nobr>TPL-BTA<\/nobr>)<br \/>\u26ac <a href=\"\/product\/wide-range-temperature-probe\/\">Wide-Range Temperature Probe<\/a> (<nobr>WRT-BTA<\/nobr>)<br \/>\u26ac <a href=\"\/product\/thermocouple\/\">Thermocouple<\/a> (<nobr>TCA-BTA<\/nobr>)<br \/>\u26ac <a href=\"\/product\/surface-temperature-sensor\/\">Surface Temperature Sensor<\/a> (<nobr>STS-BTA<\/nobr>)<\/li>\n<li><a href=\"\/product\/go-direct-temperature-probe\/\">Go Direct<sup>&reg;<\/sup> Temperature Probe<\/a> (<nobr>GDX-TMP<\/nobr>), for TI-Nspire CX II and TI-Nspire CX II CAS calculators only<\/li>\n<\/ul>\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Supported Calculator Apps Troubleshooting Additional Troubleshooting Specifications Calibration Calibrate? EasyTemp is very nicely calibrated when shipped. Most never need to calibrate. EasyTemp uses a linear&#8230;<\/p>\n","protected":false},"author":1698,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[],"tags":[1492,1533,3189,3188,720,3190],"class_list":["post-14699","post","type-post","status-publish","format-standard","hentry","tag-go-temp","tag-gotemp","tag-gotempmain-gotempmain","tag-gtpmain","tag-maintil","tag-temp"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts\/14699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/users\/1698"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/comments?post=14699"}],"version-history":[{"count":0,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts\/14699\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/media?parent=14699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/categories?post=14699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/tags?post=14699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}