{"id":1959,"date":"2013-06-26T23:18:21","date_gmt":"2013-06-27T06:18:21","guid":{"rendered":""},"modified":"2020-01-14T18:42:46","modified_gmt":"2020-01-15T02:42:46","slug":"1959","status":"publish","type":"post","link":"https:\/\/www.vernier.com\/til\/1959","title":{"rendered":"How do I enable Manual Configuration Mode in Logger Pro?"},"content":{"rendered":"<p>Manual configuration mode is a special mode of Logger <i>Pro<\/i> designed for instructors wishing to have their students set up data collection and graphing themselves. Logger <i>Pro<\/i> will no longer set data-collection rate and duration, and graphs will no longer be automatically associated with columns in the data table. Graph scaling is also no longer adjusted to suit the sensor defaults.<\/p>\n<p>This mode is intentionally difficult to defeat, so enabling it requires a minor edit to a support file of Logger <i>Pro<\/i>. The edit must be done once on each computer where Logger <i>Pro<\/i> is installed.<\/p>\n<p>Instructions for enabling manual configuration mode in Logger <i>Pro<\/i> 3.7 or newer. Earlier versions of Logger <i>Pro<\/i> do not support manual configuration mode.<\/p>\n<p>Instructions for English <b>Windows<\/b>:<br \/>\n(Macintosh instructions are later in this document.)<\/p>\n<p>1) Close Logger <i>Pro<\/i> 3.<br \/>\n2) Open the folder c:\\Program Files\\Vernier Software\\Logger <i>Pro<\/i> 3\\en-US\\Support. If the computer has 64-bit windows, the path will be c:\\Program Files (x86)\\Vernier Software\\Logger <i>Pro<\/i> 3\\en-US\\Support<br \/>\n3) Open the UserSettings.txt file in a text editor such as Notepad.<br \/>\n4) Save the file as UserSettingscopy.txt. (Note: If you are using Windows Vista or Windows 7, you will need to save the file somewhere else, such as the Your Documents folder, and then move it to the Support folder after editing.)<br \/>\n5) Search for &#8220;Manual&#8221;. This will locate the Manual Sensor Configuration portion of the User Settings file.<br \/>\n6) Set the Manual_Sensor_Config value to &#8220;1&#8221;. This will enable Manual Sensor Configuration , disabling many automatic behaviors of Logger <i>Pro<\/i>.<br \/>\n7) Save and close the UserSettingscopy.txt file.<br \/>\n8) Rename the original UserSettings.txt file to UserSettingsOriginal.txt.<br \/>\n9) Rename UserSettingscopy.txt to UserSettings.txt. Move the file to the Support folder. You may be prompted for permission. Logger <i>Pro<\/i> will now use the settings in this file.<br \/>\n10) Choose Preferences from the Logger <i>Pro<\/i> menu. Find the Startup File: checkbox, and clear it if checked. Click OK. This setting must be done once per user of the computer.<br \/>\n11) Test by connecting an interface with an auto-ID sensor, and launching Logger <i>Pro<\/i>. Logger <i>Pro<\/i> should show the presence of the interface in the toolbar, but not set up any columns or graphs for the sensor.<\/p>\n<p>Instructions for enabling manual configuration mode in Logger <i>Pro<\/i> 3.7 or newer for <b>Macintosh<\/b>. These steps assume you have permission to modify the Logger <i>Pro<\/i> Resources folder in the application bundle or can authenticate with administrative rights to obtain permission.<\/p>\n<p>1) Close Logger <i>Pro<\/i> 3.<br \/>\n2) Open the folder Applications\/Logger <i>Pro<\/i> 3.<br \/>\n3) Control-click on the Logger <i>Pro<\/i> application, and choose Show Package Contents.<br \/>\n4) Open the folder Contents, and open the folder Resources.<br \/>\n5) Open the UserSettings.txt file in a text editor such as Textedit (Note that starting with the Lion release of OS X, Textedit&#8217;s behavior has changed &#8212; specifics noted parenthetically below).<br \/>\n6) Choose File. Save As. . . to save a copy of the file as UserSettingscopy.txt. (Lion+: File &gt; Duplicate and then File &gt; Save in the duplicate window. You may need to save the file to the Desktop as an interim step.)<br \/>\n7) In the file, search for &#8220;Manual&#8221;. This will locate the Manual Sensor Configuration portion of the User Settings file.<br \/>\n8) Change the Manual_Sensor_Config value to from &#8220;0&#8221; to &#8220;1&#8221;. This will enable Manual Sensor Configuration, and disable many automatic behaviors of Logger <i>Pro<\/i>.<br \/>\n9) Save and close the UserSettingscopy.txt file.<br \/>\n10) Rename the original UserSettings.txt file to UserSettingsOriginal.txt.<br \/>\n11) Rename UserSettingscopy.txt to UserSettings.txt (and if necessary move it from the Desktop into Resources folder as above). Logger <i>Pro<\/i> will now use the settings in this file.<br \/>\n12) Close the Finder window showing the contents of the Logger <i>Pro<\/i> package.<\/p>\n<p>To <b>return to the original automatic behavior<\/b> of Logger <i>Pro<\/i> on either Mac or Windows, follow these steps. (Once again you may need to authenticate to the computer administrator to make these changes.)<br \/>\n1) Rename the current UserSettings.txt file to UserSettingsManual.txt.<br \/>\n2) Rename UserSettingsOriginal.txt to UserSettings.txt. Logger <i>Pro<\/i> will now use the settings in this file.<br \/>\n3) Launch Logger <i>Pro<\/i>. Choose Preferences from the Logger <i>Pro<\/i> menu. Place checkmarks in the two items under \u201cUpdate Screen Objects for Sensor Change:\u201d This setting must be done once per user of the computer.<\/p>","protected":false},"excerpt":{"rendered":"<p>Manual configuration mode is a special mode of Logger Pro designed for instructors wishing to have their students set up data collection and graphing themselves&#8230;.<\/p>\n","protected":false},"author":18127,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[],"tags":[2509,3097,84,3095,3096,3098],"class_list":["post-1959","post","type-post","status-publish","format-standard","hentry","tag-ib","tag-ib-mode","tag-logger-pro","tag-manual-configuration","tag-manual-setup","tag-usersettings-usersettings-txt"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts\/1959","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/users\/18127"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/comments?post=1959"}],"version-history":[{"count":0,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts\/1959\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/media?parent=1959"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/categories?post=1959"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/tags?post=1959"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}