{"id":2039,"date":"2018-03-28T18:43:41","date_gmt":"2018-03-29T01:43:41","guid":{"rendered":""},"modified":"2024-04-25T10:32:02","modified_gmt":"2024-04-25T17:32:02","slug":"2039","status":"publish","type":"post","link":"https:\/\/www.vernier.com\/til\/2039","title":{"rendered":"Can an EasyTemp or EasyLink be used with LabQuest?"},"content":{"rendered":"<p class=\"inline wp-block-paragraph\">For all LabQuest models, an <a href=\"https:\/\/www.vernier.com\/product\/easytemp\/\">EasyTemp<\/a> <img loading=\"lazy\" decoding=\"async\" width=\"75\" height=\"44\" class=\"wp-image-19904\" style=\"width: 75px;\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/04\/image-1-e1713464009381.jpeg\" alt=\"\" srcset=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/04\/image-1-e1713464009381.jpeg 1448w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/04\/image-1-e1713464009381-600x353.jpeg 600w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/04\/image-1-e1713464009381-1024x603.jpeg 1024w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2024\/04\/image-1-e1713464009381-768x452.jpeg 768w\" sizes=\"auto, (max-width: 75px) 100vw, 75px\" \/> and <a href=\"https:\/\/www.vernier.com\/product\/easylink\/\">EasyLink<\/a> <img loading=\"lazy\" decoding=\"async\" width=\"75\" height=\"42\" class=\"wp-image-6347\" style=\"width: 75px;\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2020\/01\/product.ez-link._hero.001-600x338-1.jpg\" alt=\"\">can be connected to the full size USB-A port on the LabQuest using an <a href=\"\/product\/easy-to-go-adapter\/\">Easy to Go! Adapter<\/a> (<nobr>MINI-USB<\/nobr>) <img loading=\"lazy\" decoding=\"async\" width=\"75\" height=\"42\" class=\"wp-image-6311\" style=\"width: 75px;\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2020\/03\/product.mini-usb._hero.001-600x338-1.jpg\" alt=\"\">.<\/p>\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<p class=\"inline wp-block-paragraph\">For <a href=\"https:\/\/www.vernier.com\/product\/labquest-2\/\">LabQuest 2<\/a><img loading=\"lazy\" decoding=\"async\" width=\"75\" height=\"42\" class=\"wp-image-5964\" style=\"width: 75px;\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2020\/02\/product.labq2._hero.001.600.338.jpg\" alt=\"\">, the EasyTemp and EasyLink can be connected directly to the mini-USB port typically used for connectivity with a computer. The mini-USB port on the <a href=\"https:\/\/www.vernier.com\/product\/original-labquest\/\">original LabQuest<\/a><img loading=\"lazy\" decoding=\"async\" width=\"75\" height=\"42\" class=\"wp-image-5968\" style=\"width: 75px;\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2020\/02\/product.labq._hero.001.600.338.jpg\" alt=\"\">does not support direct data collection with sensors<sup data-fn=\"160de65a-65d7-47cf-917e-64459a0101da\" class=\"fn\"><a href=\"#160de65a-65d7-47cf-917e-64459a0101da\" id=\"160de65a-65d7-47cf-917e-64459a0101da-link\">1<\/a><\/sup>.<\/p>\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<p class=\"inline wp-block-paragraph\"><a href=\"https:\/\/www.vernier.com\/product\/labquest-3\/\">LabQuest 3<\/a> <img loading=\"lazy\" decoding=\"async\" width=\"50\" height=\"36\" class=\"wp-image-8975\" style=\"width: 50px;\" src=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2019\/07\/product.labq3._002.right.screenshot-600x338-1.jpg\" alt=\"\" srcset=\"https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2019\/07\/product.labq3._002.right.screenshot-600x338-1.jpg 318w, https:\/\/www.vernier.com\/til\/wp-content\/uploads\/sites\/2\/2019\/07\/product.labq3._002.right.screenshot-600x338-1-271x198.jpg 271w\" sizes=\"auto, (max-width: 50px) 100vw, 50px\" \/> does not have a mini-USB port as it uses a micro-USB port for computer connectivity. While there are some mini-to-micro adapters, these cannot be used with LabQuest 3 for data collection through the micro-USB port.<\/p>\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<ol style=\"font-size:15px;font-style:normal;font-weight:400\" class=\"wp-block-footnotes has-background has-very-light-gray-background-color\">\n<li id=\"160de65a-65d7-47cf-917e-64459a0101da\">The difference between the mini-USB port on the original LabQuest vs the LabQuest 2 is that the LabQuest 2&#8217;s socket is a USB On-The-Go port which allows it to function as both a host or a device in the USB protocol. As such, the LabQuest 2 uses a Mini-AB USB socket which will accept both mini-B connectors (the standard cable to connect to a computer) and mini-A connectors (like those on the EasyTemp and EasyLink). The original LabQuest doesn&#8217;t have the electronics to function this way on the USB Mini port, so it just has a Mini-B socket. A Mini-A connector has a slightly different shape, so it is not designed to fit into a Mini-B socket. <a href=\"#160de65a-65d7-47cf-917e-64459a0101da-link\" aria-label=\"Jump to footnote reference 1\">\u21a9\ufe0e<\/a><\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>For all LabQuest models, an EasyTemp and EasyLink can be connected to the full size USB-A port on the LabQuest using an . For LabQuest&#8230;<\/p>\n","protected":false},"author":2166,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":"[{\"content\":\"The difference between the mini-USB port on the original LabQuest vs the LabQuest 2 is that the LabQuest 2's socket is a USB On-The-Go port which allows it to function as both a host or a device in the USB protocol. As such, the LabQuest 2 uses a Mini-AB USB socket which will accept both mini-B connectors (the standard cable to connect to a computer) and mini-A connectors (like those on the EasyTemp and EasyLink). The original LabQuest doesn't have the electronics to function this way on the USB Mini port, so it just has a Mini-B socket. A Mini-A connector has a slightly different shape, so it is not designed to fit into a Mini-B socket.\",\"id\":\"160de65a-65d7-47cf-917e-64459a0101da\"}]"},"categories":[],"tags":[2975,3267,2462],"class_list":["post-2039","post","type-post","status-publish","format-standard","hentry","tag-ez-link","tag-ez-tmp","tag-labq"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts\/2039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/users\/2166"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/comments?post=2039"}],"version-history":[{"count":0,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/posts\/2039\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/media?parent=2039"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/categories?post=2039"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vernier.com\/til\/wp-json\/wp\/v2\/tags?post=2039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}