How do I transfer files between two TI-83/84 calculators?

  • September 17, 2010
  • 0
Connect the two calculators together using the unit-to-unit cable that came with the calculators. On the Receiving calculator... Press [2nd][X,T,Ï´,n] (Link) Press the right arrow key to select Receive. Press [Enter] to see the message ...
Continue Reading →

Do you sell a Goniometer or Tilt Angle Sensor?

  • September 7, 2010
  • 0
Yes, Vernier does sell a Goniometer. Goniometer (GNM-BTA) However, if you already have our Low-g Accelerometer, you can use it to report tilt angle using our Logger Pro 3 software. The JointAngleSensorLowG.cmbl Logger Pro experiment file is c...
Continue Reading →

The lab instructions don’t match what I see on the LabQuest screen.

  • September 3, 2010
  • 0
Most of the Vernier lab books contain printed instructions specific to Logger Pro for computer. For example, the instructions will refer to opening a particular experiment file near the start of the lab. If your students are doing experiments on the...
Continue Reading →

I plugged in a LabQuest interface and it isn’t showing up in Logger Pro. (Mac only)

  • August 27, 2010
  • 0
Other symptoms: LabQuest Mini has power, but the LED stays red. LabQuest is plugged in, but the screen hasn't changed to the double arrows "connected" screen. This can happen when you have VMWare Fusion running, because by default it asks you whethe...
Continue Reading →

Why does my CO2 sensor ID as a Current sensor when used with a Go!Link?

  • August 3, 2010
  • 0
The BTA version of the CO2 Gas Sensor is not supported by the original Go!Link. (The original Go!Link label simply says Go!Link, like the one shown below, while newer versions say Go!Link by Vernier.) COâ‚‚ Sensor Original Go Link ...
Continue Reading →

Can I have my spectrometer capture full wavelength spectra episodically?

  • August 3, 2010
  • 0
Yes, you can collect a series of full wavelength spectra using Logger Pro. Spectral Analysis cannot yet perform this function. In Logger Pro, you can capture data sequentially or episodically in Intensity, Absorbance or Fluorescence modes. This is a...
Continue Reading →

Are Ethidium Bromide (ETBR) stained gels readable using a BlueView Transilluminator?

  • July 13, 2010
  • 0
Quick answer, Yes. Full answer, depends on the concentration and amount of nucleic acid present in the bands in question. Testing revealed the BlueView Transilluminator (BlueView) is capable of detecting double stranded DNA segments stained with ethi...
Continue Reading →

Does the Pasco picket fence work the same as the Vernier picket fence?

  • June 29, 2010
  • 0
The Vernier picket fence has 2.5 cm wide black stripes with 2.5 cm clear spaces between the black stripes. The Pasco picket fence (ME-9377A) has 2 cm wide black stripes with 3 cm clear spaces in between the black stripes. Since the Pasco picket fence...
Continue Reading →

How do you use the current and voltage controls of the Extech Power supply?

  • June 16, 2010
  • 0
The Extech Digital DC Power Supply (EXPS) can operate in either voltage-control or current-control modes, and so has both current and voltage control knobs. Most instructors are familiar with power supplies which have voltage controls. That is, y...
Continue Reading →

Get message “The ordinal 18 could not be located in the dynamic link library VGPS_SDK.dll” after opening Logger Pro.

  • June 15, 2010
  • 0
After upgrading from earlier versions sometimes you will get a message saying "The ordinal 18 could not be located in the dynamic link library VGPS_SDK.dll" when you try to launch the program. Delete the file C:\Program Files\Vernier Software\Logger...
Continue Reading →
  • «