Go Direct® Wide-Range Pressure Sensor

Go Direct® Wide-Range Pressure Sensor

Go Direct® Wide-Range Pressure Sensor

$199.00

Measure absolute pressures up to 690 kPa (100 psi) with excellent accuracy using Go Direct® Wide-Range Pressure, which features robust metal fittings and a leakproof seal. 

ORDER CODE: GDX-WRP Categories ,

Elevate pressure measurement with Go Direct Wide-Range Pressure Sensor. Geared toward the college level, this sensor enables students to measure absolute pressures up to 690 kPa (100 psi) with excellent accuracy. The Go Direct Wide-Range Pressure Sensor features robust metal fittings and a leakproof seal, and it can perform experiments related to Boyle’s law, vapor pressure, and other phenomena related to gas pressure. 

Rechargeable Battery—Ready When You Are

The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our award-winning Vernier Graphical Analysis™ Pro app, as well as LabQuest® 3. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wireless or Wired—The Flexibility to Choose

Our Go Direct sensors connect directly to your mobile device, Chromebook, or computer using our Vernier Graphical Analysis Pro app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory.

Specifications

  • Range up to 100 psi, ~690 kPa
  • Accuracy using factory calibration: ±2 kPa
  • Accuracy using custom calibration: ±1 kPa (one-point calibration at atmosphere)
  • Maximum pressure without damage: 900 kPa

Requirements

Choose a platform below to see its compatibility requirements.

LabQuest
InterfaceLabQuest App
LabQuest 3Full support
LabQuest 2 (discontinued)Full support 1
LabQuest (discontinued)Incompatible

Compatibility Notes

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Computers
Software
InterfaceGraphical Analysis App for Computers
No interface requiredFull support 1
LabQuest 3Full support 2
LabQuest 2 (discontinued)Full support 2 3

Compatibility Notes

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Chromebook
Software
InterfaceGraphical Analysis App for Chrome
No interface requiredFull support
LabQuest 3Full support 1
LabQuest 2 (discontinued)Full support 1 2

Compatibility Notes

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
iOS
Software
InterfaceGraphical Analysis App for iOSGraphical Analysis GW for iOS
No interface requiredFull supportIncompatible
LabQuest 3Full support 1 2Full support 2
LabQuest 2 (discontinued)Full support 1 2 3Full support 1 2 3

Compatibility Notes

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. iOS and Android devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.
Android
Software
InterfaceGraphical Analysis App for AndroidGraphical Analysis GW for Android
No interface requiredFull supportIncompatible
LabQuest 3Full support 1 2Full support 1
LabQuest 2 (discontinued)Full support 1 2 3Full support 1 3

Compatibility Notes

  1. iOS and Android devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  2. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

What's Included

  • Go Direct Wide-Range Pressure Sensor with chrome-plated brass quick-disconnect tube fitting with 1/8” NPT thread insert attached
  • Micro USB cable
  • Chrome-plated brass quick-disconnect tube fitting with 1/8” hose barb insert 
  • Plastic tubing (2-foot section) 
  • Plumber’s tape

Support

Warranty

5-year limited warranty (1 year on battery)
See our warranty policy

Contact Us

Educational use only: Vernier products are designed for educational use. They are not appropriate for industrial, medical, or commercial applications.

SAVE/SHARE YOUR CART