Ammonium Ion-Selective Electrode

Ammonium Ion-Selective Electrode

Ammonium Ion-Selective Electrode

$219.00

The Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of Ammonium (NH4+) in aqueous samples.

ORDER CODE: NH4-BTA Categories ,

Use the Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can also indicate aqueous ammonia levels if sample solutions are acidified to convert NH3 to NH4+.

The Ammonium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one.

Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.

Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.

Specifications

  • Range (concentration): 1 to 18,000 mg/L (or ppm)
  • Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L)
  • Interfering ions: K+
  • pH range: 4–7.5 (no pH compensation)
  • Temperature range: 0–40°C (no temperature compensation)
  • Electrode slope: +56 ±4 mV/decade at 25°C
  • Electrode resistance: 1–4 MΩ
  • Immersion: 2.8 cm
  • Electrode length: 155 mm
  • Body diameter: 12 mm
  • Cap diameter: 16 mm
  • Cable length: 100 cm

Experiments

Middle School (1 experiments)
High School (1 experiments)
College (1 experiments)

Requirements

Choose a platform below to see its compatibility requirements.

LabQuest
InterfaceLabQuest App
LabQuest® 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support
Computers
Software
InterfaceGraphical Analysis App for Computers
Version 4.10
Logger Pro
Version 3.16
Logger Lite
Version 1.9.4
LabQuest MiniFull supportFull supportFull support
LabQuest® 3Full supportFull supportFull support
LabQuest 2 (discontinued)Full supportFull supportFull support
LabQuest StreamFull support 1Full supportFull support 2
Go!LinkFull supportFull supportFull support
LabQuest (discontinued)Full supportFull supportFull support

Compatibility Notes

  1. Connect LabQuest Stream via USB. Future software updates will support connection via Bluetooth® technology
  2. Connect LabQuest Stream via USB. Wireless connection is not supported.
Chromebook
Software
InterfaceGraphical Analysis App for Chrome
Version 4.10
LabQuest MiniFull support
LabQuest® 3Full support
LabQuest 2 (discontinued)Full support
LabQuest StreamFull support 1
Go!LinkFull support
LabQuest (discontinued)Full support

Compatibility Notes

  1. Connect LabQuest Stream via USB. Future software updates will support connection via Bluetooth® technology
iOS
Software
InterfaceGraphical Analysis App for iOS
Version 4.10
Graphical Analysis GW for iOS
Version 4.0.6
LabQuest StreamFull supportFull support
LabQuest® 3Full support 1Full support 1
LabQuest 2 (discontinued)Full support 1Full support 1

Compatibility Notes

  1. iOS and Android devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Android
Software
InterfaceGraphical Analysis App for Android
Version 4.10
Graphical Analysis GW for Android
Version 3.2
LabQuest StreamFull supportIncompatible
LabQuest® 3Full support 1Full support 1
LabQuest 2 (discontinued)Full support 1Full support 1

Compatibility Notes

  1. iOS and Android devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
Arduino
Software
InterfaceArduino
Vernier Arduino® Interface ShieldFull support 1

Compatibility Notes

  1. Requires advanced programming for data collection
LabVIEW
Software
InterfaceNI LabVIEW
SensorDAQFull support 1
Vernier myDAQ AdapterFull support 1 2
Go!LinkFull support 1
LabQuest MiniFull support
LabQuest StreamFull support
LabQuest® 3Full support
LabQuest 2 (discontinued)Full support
LabQuest (discontinued)Full support

Compatibility Notes

  1. Requires advanced programming for data collection
  2. You can only read the raw count/raw voltage output by this sensor. You must do the programming to convert to proper sensor units.
Texas Instruments
Software
InterfaceEasyData
Version 2.4/4.0/5.2
DataMate
Version 1.15
TI-84 SmartViewDataQuest
Version 4.2
TI-Nspire Software
EasyLinkFull support 1IncompatibleFull support 2Full supportFull support 2
CBL 2Full support 3Full support 3 4IncompatibleIncompatibleIncompatible
TI-Nspire Lab Cradle (discontinued)IncompatibleIncompatibleIncompatibleFull supportFull support

Compatibility Notes

  1. Use with TI-84 Plus calculators only.
  2. Requires an Easy to Go! adapter
  3. CBL 2 and LabPro interfaces cannot be used with TI-84 Plus CE calculators.
  4. DataMate cannot be used with color screen TI-84 Plus calculators; use EasyData with these calculators.

What's Included

  • Vernier Ammonium Ion-Selective Electrode
  • 30 mL bottle of Ammonium Low Standard (1 mg/L)
  • 30 mL bottle of Ammonium High Standard (100 mg/L)
  • Short-term ISE soaking bottle
  • User manual

Accessories

AccessoryOrder CodePriceQuantity
Electrode SupportESUP$10.00

Support

Educational use only: Vernier products are designed for educational use. They are not appropriate for industrial, medical, or commercial applications.